OPERATIONS
PRIMING THE PUMP
Priming refers to the pump expelling all air in the system and
beginning to move water from its source out into the system.
It does not refer only to pouring water into the pump (although
pouring water in is usually the first step).
1.
Make sure suction and discharge valves and any hoses on
discharge side of pump are open.
2.
Remove priming plug. Fill pump and suction pipe with water
(Figure 9). NEVER run pump dry. Running pump without
water in it will damage seals and can melt impeller and
diffuser. Be sure discharge (valve, pistol grip hose nozzle,
etc.) is open whenever pump is running.
If a priming tee and plug have been provided for a long
horizontal run, be sure to fill suction pipe through this
tee and replace plug. Remember to tape the plug.
Replacing the existing priming plug with one that has a
pressure gauge and reducer bushing mounted in it will
make troubleshooting pump performance easier.
FIGURE 9 – REMOVE PRIMING PLUG AND FILL PUMP BEFORE STARTING
P15006 (02-01-2023)
3.
Start pump. Water should be produced in 10 minutes or
less. The time depends on the well's depth to water and
the length of horizontal run. If no water is produced within
10 mins., stop pump, release all pressure, remove priming
plug, refill, and try again.
AND SCALDING. If pump is run con ti nu ously at no flow (that is,
with discharge shut off or without priming), water may boil in
pump and piping system. Under steam pressure, pipes may
rupture, blow off of fittings or blow out of pump ports and
scald anyone near.
FIGURE 10 – DO NOT RUN PUMP WITH DISCHARGE SHUT-OFF
3025 0997
HAZARDOUS PRESSURE AND RISK OF EX PLO SION
3026 0997