Do not switch the power on and off at rapid intervals, as this will reduce the working
life of the laser cell.
-
Always disconnect the appliance from the mains if it is out of use for a long period.
-
In the event of a serious operational problem, shut the appliance down and contact
your retailer immediately.
-
Important: never gaze directly at the laser! Do not use the appliance in the
presence of any persons who suffer from epilepsy.
Useful tip: each time you turn the appliance on, the motors will return to their 'initial' position
by default, which means you will hear some noise for a few seconds, after which the
appliance will be ready to function normally.
The BIRD LAZZZER operates completely automatically. No setting or adjustment is required.
The appliance functions in such a way that the laser beam uses the maximum available
space. The rapid movement of the laser beam frightens birds, making them take flight.
The BIRD LAZZZER is programmed to operate for 900 seconds (15 minutes), then pause for
900 seconds (15 minutes). During its active phase, the laser beam will scan at random in any
and every direction. It is normal for it to go out from time to time. After 900 seconds (15
minutes) of action, the laser beam will go out for 900 seconds (15 minutes) for its resting
phase. The monitor lights on the appliance will continue to function: the blue 'laser' monitor
will flash, and the ventilator will continue in operation in order to cool the internal components
of the appliance. After 900 seconds at rest, the appliance will resume its activity cycle.
It is inadvisable to use the appliance during daylight hours as this limits its effectiveness. The
appliance is much more effective when operating in twilight, or at night, than in broad daylight.
MAINTENANCE
-
Make sure the area below the installation site does not contain any itinerant
persons during maintenance operations.
-
Turn off the power-supply, disconnect the power cable and wait until the appliance
has cooled down.
The following points must be checked during inspections:
-
All screws used to install the appliance and its components must be securely fixed
and must not be corroded.
-
Supporting fixtures and structures (ceiling, girders, suspension) must be completely
intact and show no distortion or buckling.
-
If a vision lens is visibly damaged (i.e. deep cracks or scratches), it must be
replaced.
-
Cables must be in perfect condition. They are to be replaced without delay if any
problem is identified, however benign.
-
In order to protect the appliance from overheating, ventilators and air-vents must be
cleaned every month.
-
The appliance interior must be cleaned annually, using a suction cleaner or air jet.
-
Cleaning of internal and external vision lenses and / or mirrors must be carried out
from time to time to maximise light generation. The frequency of cleaning will
depend on the setting in which the appliance is being used: humid, smoky or
particularly dirty environments can produce a greater accumulation of dirt on the
appliance's optics.
-
Clean using a soft cloth and cleaning products used for normal glass.
-
Always dry off thoroughly.
-
Clean the external optics at least once a month.
-
Clean the internal optics at least once every 3 months.
Note: We strongly advise that you have internal cleaning carried out by qualified personnel.
SPECIFICATIONS
Power supply:
AC 230 V – 50 Hz
Fuse:
250 V 1.5 A slow (20mm glass)
Power of the laser:
full LD green diode 50mW 520nm
Laser class:
3B
Laser safety standard:
EN60825-1: 1994 + A1: 2002 + A2: 2002
Size:
25,3 x 15,3 x 8,7 cm
Weight:
1,945 Kg
Any of this information may be revised without prior
notice. You can download the latest version of these
directions for use at our website: www.weitech.com
BIRD LAZZZER 16/11/2020

Publicidad