3. Technical Data
Electrical connection, primary ......................................................... 230 V/50 Hz
Inlet pressure ................................................................................... 0-6 bar
Max. operating pressure ................................................................. 10 bar
Suction capacity (with 1" line, 15°C) ............................................... 5m/-0,5 bar
Yield ................................................................................................. approx. 60 %
Water temperature ......................................................................... 5°C-25°C
Required power ............................................................................... at 15°C
Salinity in raw water ....................................................................... max. 1000 mg/l
Salt retention rate ........................................................................... 100 % (resin filter)
Blocking index ................................................................................ max. 3
SiO2 content in raw water .............................................................. 20 mg/l
Permeate output at 15°C water temperature l/h .......................... 300-350l
Pump connection ............................................................................. 0,75 kW
Standard feed water connection ................................................... G3/4"
Standard concentrate connection .................................................. G3/4"
Standard permeate connection ...................................................... G3/4"
Height ............................................................................................... 1230 mm
Width ................................................................................................ 580 mm
Depth ................................................................................................ 510 mm
Weight ............................................................................................. approx. kg 55
3.1. Scope of delivery
1.
Robust trolley
2.
Water supply connection
3.
Pre-filter
4.
Pressure gauge water inlet downstream pre-filter
5.
Main membrane
6.
Secondary resin filter
7.
Concentrate outlet
8.
Pump control system
9.
Permeate outlet
10. Pump
11. TDS meter
12. Pressure indicator, pump
13. Pressure relief valve
•
Filter wrench, pre-filter (small)
•
Filter wrench, pre-filter (large)
•
Feed pipe for preservation
H
F
™ Ro-M
i
lo
Technical Data
www.ungerglobal.com
obile
5
6
4
2
3
1
10
12
11
9
8
13
7
21