Unused machines and machine tools should be kept in a dry, closed room. Keep them free from
damaging influences such as damp, frost or large temperature fluctuations as well as mechanical
damage.
Worn/ defect machine tools must be disposed of according to regional/ national specifications.
Fully disassemble machine for the necessary disposal.
Separate materials according to local environmental specifications.
In case of disturbances check, if all instructions contained in this technical documentation are
adhered to and make the appropriate adjustment, if needed.
The following table shows possible problems and causes:
Problem, Cause, Remedy
Problem
Insufficient performance
-
-
-
Machine doesn't start
If necessary, send the machine to the manufacturer.
42
STORAGE
DISPOSAL
TROUBLESHOOTING
Cause
Restrictions in the air line
Operation pressure too low
Filter holder dirty
Hose diameter too small
No air supply, shut-off valve
closed
Remedy
Remove restrictions
Stick to flow pressure
Replace filter holder
Specified hose diameter
Open shut-off valve