(1*/,6+ ,QVWUXFWLRQV PDQXDO
Before making any electric hook up, check to be certain that the mains voltage corresponds to that stamped on the voltage tag (at-
tached to the cord near the tyre changer's plug).
It is absolutely essential that :
- the system is equipped with a good grounding circuit.
- The machine is connected to a power supply
line circuit breaker set for 30 mA.
- The power socket take is adeguately pro-
tected against overcurrents with fuses or
circuit-breakers with rated values as shown
in the table below.
Note the required power draw as highlighted on the data plate fixed to the tyre changer.
Check to make sure the shop electric wiring circuit is dimensioned sufficiently to carry this.
Work on the electric system, even if minor, must be done
exclusively by professionally qualified personnel.
Manufacturer shall not be liable for any injury to persons
or damage to property caused by failure to comply with
these regulations and can cancel warranty coverage.
TURNING DIRECTION CHECKS
Connect the machine to the mains, switch "ON" (2, fig. H) and check that
the hydraulic power pack motor rotation corresponds to the indicating ar-
row (1, fig. L).
Otherwise, have an electrician switch two wires in the power supply plug.
The console (Fig. H) has all the controls for operating the tyre changer.
It is installed on a mobile arm so that it is always within reach while you are working on a wheel, or can be moved out of the way during
wheel loading or unloading.
The following controls are on this console:
- Main switch (2, Fig. H) Activates and deactivates the tyre changer power source and can also be used as an emergency STOP switch.
- The top lever (1, Fig. H) activates movements of the horizontal carriage to the right or left.
- The side lever (3, Fig. H) is used to raise or lower the vertical carriage.
- The bottom lever (4, Fig. H) activates clockwise or anti-clockwise wheel rota-
tion.
NB: all the controls on the console are extremely sensitive, so as to allow very
small movements with the utmost precision.
WARNING!
During all operations, keep hands and other parts of the
body as far as possible from moving parts of the machine.
Necklaces, bracelets and too large clothes, can be
dangerous for the operator.
6.5 ELECTRIC HOOK UP
POWER SUPPLY
230V - 3Ph - 50/60Hz
400V - 3Ph - 50/60Hz
7. IDENTIFYING CONTROLS
27
RATED CURRENT
FUSE
25A AM
16A AM
2
SWITCH
25A
16A
1
L
1
3
4
H
TTC 500