AIR PURGE PROCEDURE
IMPORTANT! Before first use, perform the
following air purge procedure to remove
any air that may have been added into the
hydraulic system due to product shipment
and handling. Complete this step without any
weight on the jack.
1.
Remove the cover plate by unfastening the screws.
(See Figure 6)
Figure 6
Cover Plate
2. Using handle, turn the release valve
counterclockwise one full turn to the open position.
(See Figure 7)
Figure 7
Release
Valve
3. Rapidly pump the handle 6-8 times. Leave the
handle in the down position to expose the oil fill
plug. (See Figure 8)
Figure 8
PAGE 3 OF 21
ASSEMBLY CONTINUED
4. With a flathead screwdriver, push the oil fill plug
slightly to the side to purge trapped air from the
system. Ensure oil fill plug is securely in place after
purging trapped air. (See Figure 9)
5. Replace the cover plate by fastening the screws
(See Figure 10)
6. Using handle, turn the release valve clockwise to the
closed position. (See Figure 11)
7. The jack is now ready for use. Check for proper
pump action.
Figure 9
Oil Fill Plug
Figure 10
Cover Plate
Figure 11
Release
Valve
1222 IH-10467