6. Use a funnel to fill the oil case until oil level is just
beneath the lower rim. Keep dirt and other foreign
materials clear when pouring. (See Figure 17)
Figure 17
Funnel
7.
Replace oil plug. (See Figure 18)
Figure 18
8. Replace cover plate by fastening the screws and
perform the air purge procedure. (See Figure 19)
Figure 19
Cover Plate
PAGE 6 OF 21
MAINTENANCE CONTINUED
RUST PREVENTION
1. Check rams and pump plungers on the hydraulic
2. Without a load, lift the equipment as high as it goes
STORING THE JACK
1.
2. Place the handle in the upright position.
3. Store in a dry location, recommended indoors.
unit assemblies daily for any signs of rust or
corrosion.
and look under and behind the lifting points. If signs
of rust are visible, clean as needed.
Lower the lifting arm.
NOTE: If the jack is stored outdoors, be sure
to lubricate all parts before and after use
to ensure the jack stays in good working
condition. Always store jack in the fully
retracted position when stored in outdoor or
caustic environments that can cause corrosion
and/or rust.