6. INSTALLATION
6.1
Checking the packaging
As soon as the package is received, inspect it, check that it is not upside down and that it has not been
damaged during transport. Then remove the packaging, inspect the machine, and make sure that there are
no damages in the cooling circuit (the presence of oil on the pipes indicates a crack or break in the circuit).
If there are doubts about the integrity of the system components, do not use the machine. Report any
damage and / or anomalies to the dealer within 24 hours from the date of purchase.
6.2
Air conditioner positioning
The air conditioner is designed to supply air directly from the air-conditioned room; therefore, it must be
installed in one of the rooms to be conditioned.
Do not install the air conditioner in environments from which harmful vapours or fumes
could be extracted (engine room, bilge, environments containing combustion engines, fuel
tanks, gas cylinders, etc.).
Identify a flat well-levelled surface, suitable to bear the weight of the air conditioner with free space on each
side such as to ensure good air circulation and to facilitate installation and maintenance operations.
The air conditioner can be installed in the two configurations shown in figure 2. Figure 2a represents the
optimal installation, the machine is installed with the evaporator in front of the air intake grille, or in figure
2b the machine is rotated 90 ° with respect to the supply grille.
If the installation shown in figure 2b is used, a distance between the front wall and the
evaporator of 100 mm must be maintained.
A = suction grill
B = 100 mm
2a
Fig. 2 (positioning of the machine)
61
2b