3 Product description
2.3 Emergency information
In the event of an emergency, immediately disconnect the following supplies:
• Electrical power supply
• Gas supply
Additional measures can be found in the operating instructions for the power source or the documentation for other
peripheral devices.
3 Product description
WARNING
Hazards caused by improper use
If improperly used, the device can present risks to persons, animals, and material property.
• Use the device according to its designated use only.
• Do not convert or modify the device to enhance its performance without authorization.
• The device may be used only by qualified personnel (in Germany, see TRBS 1203).
3.1 Technical data
Ambient temperature
Relative humidity
Media temperature
Mechanical data/other:
Material
Weight
Dimensions W x H x D
Protection type
Fitting position
Communication via jack
Communication via CANopen, Ethernet
Process medium:
Pressure range (relative pressure)
Pressure flow range
Fluidic connectors
Gas input pressure range
Electrical data:
Operating voltage
Max. power consumption
Connections
Active regulation of gas volume flow
Recording of gas consumption
Shunt types
CAN interface
(e.g. for communication with other systems)
Tab. 2
Technical data
EN - 4
EWR 2 / EWR 2 Net
EWR 2
−10 °C to +50 °C
20 to 90%
+10 °C to +40 °C
Housing: Aluminum, black lacquer
Approx. 670 g
178.5 × 83 × 51 mm
IP54
Wall mounting, connectors at the bottom
x
/
p
= 1–6 bar / p
= max. 2 bar
IN
OUT
Q
= 2 to 30 ± 1 l/min
air
Hose connectors, 6 mm
1–6 bar
24 V DC ± 20%
10 W
Fig. 1 on page EN-7 / 6.4 on page EN-9
x
ABICOR BINZEL Service software
150 A / 300 A / 500 A
/
6.5 on page EN-9
BAL.0598 • 2018-04-09
EWR 2 Net
x
x