3.1
HEAT MODE
3.2
t_T4_FRESH_H
3.3
T4HMAX
3.4
T4HMIN
3.5
dT1SH
3.6
dTSH
3.8
T1SetH1
3.9
T1SetH2
3.10
T4H1
3.11
T4H2
3.12
ZONE1 H-EMISSION
3.13
ZONE2 H-EMISSION
3.14
t_DELAY_PUMP
4.1
T4AUTOCMIN
4.2
T4AUTOHMAX
5.1
WATER FLOW TEMP.
5.2
ROOM TEMP.
5.3
DOUBLE ZONE
6.1
ROOM THERMOSTAT
7.1
dT1_IBH_ON
7.2
t_IBH_DELAY
7.3
T4_IBH_ON
7.4
dT1_AHS_ON
7.5
t_AHS_DELAY
7.6
T4_AHS_ON
7.7
IBH_LOCATE
7.8
P_IBH1
7.9
P_IBH2
7.10
P_TBH
8.1
T1S_H.A_H
8.2
T5S_H.A_DHW
PREHEATING FOR
12.1
FLOOR T1S
12.3
t_FIRSTFH
Enable or disable the heating mode
The refresh time of climate related curves for heating
mode
The maximum ambient operating temperature for heating
mode
The minimum ambient operating temperature for heating
mode
The temperature difference for starting the unit (T1)
The temperature difference for starting the unit (Ta)
The setting temperature 1 of climate related curves for
heating mode
The setting temperature 2 of climate related curves for
heating mode
The ambient temperature 1 of climate related curves for
heating mode
The ambient temperature 2 of climate related curves for
heating mode
The type of zone1 end for heating mode 0=FCU(fan coil
unit) 1=RAD.(radiator) 2=FLH(floor heating)
The type of zone2 end for heating mode 0=FCU(fan coil
unit) 1=RAD.(radiator) 2=FLH(floor heating)
the time that the compressor has run before starting the
pump.
The minimum operating ambient temperature for cooling in
auto mode
The maximum operating ambient temperature for heating
in auto mode
Enable or disable the WATER FLOW TEMP.:0=NON,1=YES
Enable or disable the ROOM TEMP.:0=NON,1=YES
Enable or disable the ROOM THERMOSTAT DOUBLE
ZONE:0=NON,1=YES
The style of room thermostat
0=NON,1=MODE
SET,2=ONE ZONE,3=DOUBLE ZONE
The temperature difference betw een T1S and T1 for
starting the backup heater.
The time that the compressor has run before the first
backup heater turns on
The ambient temperature for starting the backup heater
The temperature difference betw een T1S and T1B for
turning the additional heating source on
The time that the compressor has run before starting the
additional heating source
The ambient temperature for starting the additional
heating source
IBH/AHS installation location PIPE LOOP=0; BUFFER TANK=1
Power input of IBH1
Power input of IBH2
Power input of TBH
The target outlet w ater temperature for space heating
w hen in holiday aw ay mode
The target outlet w ater temperature for domestic hot
w ater heating w hen in holiday aw ay mode
The setting temperature of outlet w ater during first
preheating for floor
The time last for preheating floor
1
0
0.5
0.5
25
20
-15
-25
5
2
2
1
35
25
28
25
-5
-25
7
-25
1
0
2
0
2
2
25
20
17
10
1
0
0
0
0
0
0
0
5
2
30
15
-5
-15
5
2
30
5
-5
-15
0
0
0
0
0
0
2
0
25
20
25
20
25
25
72
48
56
1
1
/
6
0.5
hours
35
1
15
1
10
1
10
1
60
1
60
1
35
1
35
1
2
1
/
2
1
/
20
0.5
MIN
29
1
17
1
1
1
/
1
1
/
1
1
/
3
1
/
10
1
120
5
MIN
10
1
10
1
120
5
MIN
10
1
0
0
20
0.5
kW
20
0.5
kW
20
0.5
kW
25
1
25
1
35
1
96
12
HOUR
V.2