Installing the machine
M4. Insert the hose connection into the opening for the air
extraction system of the machine. Ensure it is firmly
connected.
Fig. 12: Inserting the hose connection into the opening for the air
extraction system
The installation of the suction hose with the hose con-
nection is complete.
4.5.4 Installing the switching unit
M1. Connect the power cable of the suction device to the
switching unit.
M2. Connect the control cable of the switching unit to the
switching output at the connection panel of the Ma-
chine.
M3. Plug the switching unit into a power socket.
Fig. 13: Connecting the switching unit to the suction device and the
machine
16
4.6 Establishing the electric connection
Damaging of the machine through heavy
voltage fluctuations
Heavy voltage fluctuations can disrupt the control unit and
can cause system failures.
h Plug the machine's power cord in a dedicated circuit cur-
h If heavy voltage fluctuations cannot be avoided, install a
M1. Plug the provided power cord into the power connec-
M2. If power failures occur regularly at your location, install
n
M3. Put the plug of the cord into a socket that is protected
4.7 Connecting the CAM computer
M1. Switch on the machine.
M2. Close the working chamber door.
M3. Start the CAM computer.
M4. Use the provided USB cable to connect a USB port of
S5.
S6.
S7.
S8.
n
Original Operating Instructions: K4 edition
Document version: E – 02/2020
NOTICE
rent or ensure that no devices are connected that can
cause heavy voltage fluctuation when switched on.
suitable device which protects the machine from heavy
voltage fluctuations.
tion at the connection panel of the Machine.
a suitable Uninterruptible Power Supply (UPS).
If a power failure occurs during job execution, the tool
may break and the blank may be destroyed.
by a Residual Current Device / Ground Fault Circuit In-
terrupter.
your computer or docking station with the connection
panel of your Machine.
Install the newest version of DentalCAM and DentalCNC
that is released for the machine. For more information
on this, read the documentation for the applications.
Start DentalCNC and click on the depicted icon
in the icon bar.
Click on the depicted icon in the lower icon
bar.
The application settings view displays.
Click on the depicted icon beside the text Port
number.
DentalCNC will try to establish a connection to the Ma-
chine. If this is successful, the application will display
the port number beside the icon and the machine ref-
erences.
The machine will not reference if the working chamber
door is open.