4
Push till connector locks into position.
(Picture 4 is showing top cable exit version).
7
Push on the shielding cover, as shown,
until it locks at same time that cable is
fixed with the tie-wrap in order to get
grounding connection.
10
Install the insert (not included in the kit; it
must be ordered separately) by means of
align the latches and the slots.
13
When changing the insert, remove the
front- panel and extract the insert by means
of tool PN 949157-1 (fig. 13 and 14).
Rev C
5
In order to assy. the shielding cover is
necessary to
corresponding tab (left, right or top),
according to previously selected cable exit.
As example, Fig. 5 shows the top tab
bended.
8
Cut the tie end. Metal tab is in contact with
metal braid and drain wire (if any). Tie is
working as a strain relief for cable retention.
11
Insert the front panel.
Complementary information (removing parts from environment)
14
If extraction tool is not available, use a small
screwdriver to unlock the latches.
bend
manually 90º
the
6
Insert the tie through the tab hole. (As
shown in top cable exit / fig.6).
9
Install the housing into the wall mounted
box (as shown). Four locking tabs hold
the housing in position.
12
AMP CO Plus kit is already installed.
15
In order to remove the housing, press
down the four latches (2+2) and unlock
the housing from box frame.
411-93010
Tie
Tie
2 of 4