Pre-installation
ELECTRICAL REQUIREMENTS
□
Product rating is 120 volts AC, 60 Hertz, 15 amps and 1.6 kilowatts.
□
This product must be connected to a seperate and dedicated supply circuit of the proper voltage and frequency.
□
Wire size must conform to the requirements of the National Electrical Code or the prevailing local code for this kilowatt rating.
□
The power supply cord and plug should be brought to a seperate and dedicated 15-to 20-ampere branch circuit single grounded outlet.
□
The outlet box should be located in the cabinet above the microwave oven.
□
The outlet box and supply circuit should be installed by a qualifed electrician and conform to the National Electrical Code or the
prevailing local code.
DAMAGE—SHIPMENT/INSTALLATION
□ If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement.
□ If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
□ If the unit is damaged by the installer (if other than the customer), repair or replacement must be made by arrangement between
customer and installer.
TOOLS REQUIRED
Drill Bit
Electric Drill
Scissors
Tin Snips
Measuring Tape
Electric Drill Saw
Level
Wood Block
4
Electrical Tape
Phillips Screwdriver
Stud Finder