TRG13: version with mechanical/capillary thermostat and thermal fuse, closed
control, ABS housing IP67
A ) DESCRIPTION:
The heater consists of two parts. The heating section consists of three heating elements (of
the specified material) in a U-shape attached to the head with an M48x2 or G6/4" thread. The terminal plate
is made of PVC moulding with IP67. It includes a control capillary thermostat in the specified temperature
ranges and a thermal fuse to stop the heater from overheating, and a control knob with a marked scale. The
TRG13 heater always comes with the power cable passing through the OBO-VTEC grommet at the bottom of
the housing. The heater is designed to directly heat any liquid (it is necessary to adapt the material the heater
is made from). The heater's head must be fully submerged in the liquid at all times during operation. Suitable
for applications where it is necessary to immediately
control the temperature of the liquid
Fig. 12) TRG13 - Description of mechanical parts
A
TABLE 9) DESCRIPTION OF MECHANICAL PARTS
A
Heating rods 8.5 mm + sensor sump
B
Process connection G6/4" or M48x2
C
Electrical grommet
D
PVC housing IP67
Figure 13) TRG13 - Description of internal components
A
A
G H
G H
I
I
G H
B
TABLE 10) DESCRIPTION OF INTERNAL COMPONENTS
A
Bottom part of PVC housing 1x230V
B
Bottom part of PVC housing 3x230V
C
Bottom part of PVC housing 3x400V
D
Bottom part of PVC housing with 1F combi thermostat
E
Bottom part of PVC housing with 3F combi thermostat
F
Upper part of PVC housing
G
Terminal plate for heating rods
• info@thermis.cz • www.thermis.cz •
B B
C
I
C
G
H
I
• (+420) 545 226 177-184 •
D
D
K M
E
L
M
J
H
Thermostat and thermal fuse sensor sump
I
Earthing clamp
J
Thermostat holder in the lower part
K
1F combi thermostat
L
3F combi thermostat
M
Control dial
• Thermis, spol. s r.o. • Mateří 14 •
• 614 00 Brno • Czech Republic •
C
D
F
J