flashing light
grenn
flashing light
red/green
flashing light
red
COMMISSIONING WITH OPTIONAL 12 V RECHARGEABLE BATTERY (PG.35/
FIG.3,4 & PG.36/FIG.6):
Place the batteries charged to 34 Ah in the lower section 87100 (12 Ah with inter-
mediate plate 87102). Place larger rechargeable batteries next to the device (see
PG. 34/FIG.2b). Then connect the device to the 12 V rechargeable battery (red +
/ black -), ensure correct polarity and make sure the pole terminals are clean. The
connecting cable is included with the super fleece rechargeable battery! Use the
optional connecting cable (905010) for the 12 V special rechargeable battery. After
a few seconds you will hear a steady ticking indicating the device is in operation.
The device will not start if the polarity is reversed.
Only use rechargeable 12 V lead batteries; rechargeable batteries with
ventilation should only be recharged in well-ventilated rooms. When
charging with a charger that is not listed in these instructions and is con-
nected directly to the 12 V lead battery, you must remove the rechargeable
battery from the device. The rechargeable battery should be stored and
charged at normal room temperature before and after every use as well as
during longer periods of storage in the house (every 2 months).
The rechargeable battery must be recharged by the latest when it has discharged
80 % (only 20 % charge capacity left) to prevent complete discharge. The rechar-
geable battery indicator (PG.34/FIG.2a /
flashing light
green
flashing light
red/green
flashing light
red
Please note that the values can fluctuate depending on the temperature (capacity)
and measurement deviations (voltage). For solar module operation, check the
rechargeable battery indicator only at dawn (without sunlight).
You can operate the device with the recommended optionally available mains ad-
apter, or charge the rechargeable battery with the optional solar module in the sun
or alternatively with the 230 V mains adapter. End the charging process as soon as
the green light of the battery indicator lights up.
Avoid overcharging the rechargeable battery!
6
residual capacity
15-100 %
5-10
%
5
%
) glows:
1
residual capacity
20-40 %
0-20 %
Battery good
Replace battery
Battery fully depleted: Replace
the 9 V battery immediately
Rechargeable battery good
40-100 %
Charge battery
Rechargeable battery fully
depleted: Recharge
immediately