Performance
SKU
HP
SWW05007K
1/2
SWW10007K
1
SKU
HP
SWF05004K
1/2
SWF10004K
1
Safety Information
WARNING:
SEE BELOW FOR LIST OF WARNINGS
1. To reduce the risk of electrical shock, a properly grounded receptacle or control box must be installed in accordance
with the governing codes. Never remove ground pin from plug.
2. Make certain that the ground fault interrupter protected receptacle or control box is within the reach of the pump's
power supply cord. DO NOT USE AN EXTENSION CORD. Extension cords that are too long or too light do not deliver
sufficient voltage to the pump motor, and they could present a safety hazard if the insulation were to become
damaged or the connection end were to fall into a damp or wet area.
3. Make sure the pump's electrical supply circuit is equipped with fuses or circuit breakers of proper capacity. A
separate branch circuit is recommended, sized according to the local electrical codes for the current shown on the
pump name plate.
4. Testing for ground. As a safety measure, each electrical outlet should be checked for ground using a circuit analyzer
which will indicate if the power, neutral and ground wires are correctly connected to your outlet. If they are not, call a
qualified licensed electrician.
5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE HANDLING. If
pump is wired direct, de-energize the circuit at the control box. Wear insulated protective shoes and do not stand in
water. Pumps equipped with a 3-prong ground plug are designed to help protect against electrical shock. DO NOT,
UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND PIN.
6. Installation and servicing of the pump, electrical circuits and hardware should only be performed by a qualified,
licensed electrician.
7. Risk of electrical shock. Do not remove power supply cord and strain relief or connect conduit directly to the pump.
If the supply cable is damaged, it must be replaced by the Manufacturer or an Authorized Service and Warranty
Center to avoid a hazard.
8. Pump contains oil which becomes pressurized and hot when operating. Allow 2-1/2 hours after disconnecting
before attempting service.
9. Pump is not intended for potable water due to possible contamination by oil contained in the pump.
10. Risk of electrical shock. These pumps have not been investigated for use in swimming pools and marine areas.
CAUTION:
SEE BELOW FOR LIST OF CAUTIONS
1. Check to be sure your power source is capable of handling the voltage requirements of the motor, as indicated on
the pump name plate.
2. The installation of variable level float switches is the responsibility of the installing party, and care should be taken
that the tethered float switch will not hang up on the pump apparatus or pit peculiarities and is secured so that the
pump will shut off. It is recommended to use rigid pipe and fittings and the pit be 18" (46 cm) or larger in diameter.
3. Vent hole. It is necessary that all submersible sump, effluent, and sewage pumps capable of handling various sizes
of solid waste be of the bottom intake design to reduce clogging and seal failures. If a check valve is incorporated in
the installation, a 3/16" (5 mm) vent hole must be drilled in the discharge pipe below the check valve and pit cover to
2
GPM of Water @ Total Feet of Lift
0 ft.
5 ft.
10 ft.
142
138
118
183
179
155
GPM of Water @ Total Feet of Lift
0 ft.
10 ft.
20 ft.
61.7
60
59
61.7
61
60
15 ft.
20 ft.
25ft.
95
67
32
130
110
83
30 ft.
40 ft. 50ft.
60ft.
55
46
33
58
55
40
For Professional Technical Support call 1-844-242-2475
Max. Lift
30ft.
/
29 ft.
47
34 ft.
70ft.
80ft.
/
/
15
30
20
42
Max. Lift
70 ft.
90 ft.