ERROR CODES, TROUBLESHOOTING
Error code
E0
E1
F1
F2
F3
F4
F5
Problem
The device does not
work,
compressor does not
switch on.
The compressor is
working,
but the refrigerator
is not cooling.
Compressor
has been working
for some time,
but it is not
cooling correctly.
Parameter
NTC thermistor
failure
Compressor failure
Possible cause
No power or
incorrect
connection
to power supply.
Blown
fuse
of the refrigerator.
Leakage of the
refrigerant through
the evaporator.
Incorrect
circulation
of air
around the device,
the fan does not
work correctly,
Possible cause
-
Input voltage too low.
Damaged fan.
Control unit error or
compressor blocked.
Compressor speed too low.
Environment temperature
too high.
Solution
Check input
voltage, battery
and connection
to power supply.
Replace with
a working fuse – its
socket is located
on the red
wire for the
connection to
to power supply.
Check the device
for leakage,
supplement the
refrigerant.
Improve
circulation/ventilation
around the device,
check the fan
status, check the
drawer closure