ENGLISH
Floor mounting (optional kit)
The appliance can be horizontally floor mounted using
the special optional kit.
Pipework connections
9
(fig. 9).
3
EXTRACT
SUPPLY
TO
FROM
EXTERNAL
EXTERNAL
The spigots on the appliance measure 125 mm in
diameter. Ducts may be connected to the appliance inlet
and outlets. Each connection is illustrated below with a
diagram that shows the direction of the air flow (in and
out).
Stale air outlet
(fig. 10).
10
This outlet is used to expel stale air once it has been
treated by the heat exchanger. The ducting for this stale
air must be thermally insulated (to prevent the formation
have
condensation
components) and devices fitted to absorb
the drainage system is on the roof, it must be designed
so as to prevent the formation of condensation and the
entry of rain water.
24
EXTRACT
SUPPLY
FROM
TO
INTERNAL
INTERNAL
on
internal
and
vibration.
Fresh air inlet
11
(fig. 11)
This inlet is used for carrying fresh air from the exterior;
the duct must be thermally insulated and have devices
fitted to absorb vibration. If air intake system is on the
roof, it must be designed so as to prevent the formation
of condensation and the entry of rain water.
Stale air extraction inlet
12
(fig. 12)
This inlet carries extracted stale air from the house. The
duct needs to be thermally insulated.
external
If