Descargar Imprimir esta página

STAMOS S-LS-113 Manual De Instrucciones página 23

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 73
a) Serial operation mode
To enter serial operation mode, press and hold the CH1 button for 3 seconds, the
device is ready to operate in this mode when the SER indicator (10) lights up on the
display. In this mode, CH2 is the master and CH1 is the slave.
b) Parallel operation mode
To enter parallel operation mode, press and hold the CH2 button for 3 seconds, the
device is ready to operate in this mode when the PARA indicator (10) lights up on the
display. In this mode, CH2 is the master and CH1 is the slave.
3. Recalling settings saved in memory
- Press one of five buttons M1-5 (7) to recall the saved settings.
- To save the parameters in the corresponding cache memory (7), select one of the
five buttons M1-M5, then select CH1/CH2 and make the settings as described in
section 3.3 subsection 1c), after making the settings wait until the cursor indicating
the digit being modified stops flashing.
4. Overcurrent protection (OCP)
To switch on the overcurrent protection press the OCP button (4). An illuminated OCP
indicator (11) indicates that the protection is switched on. To switch off the
overvoltage protection briefly press the OCP button again (4). The indicator will go off.
- To check the OCP values or make changes to the values, press and hold the OCP
button (4) for 3 seconds. Current OCP values for CH1 and CH2 channels will be
displayed. Turn the knobs (8 and 9) to change OCP values . To exit the configuration
setting function, press and hold the OCP button (4) again for 3 seconds.
CAUTION! If protection is switched on and the voltage values exceed the configured
maximum levels, the output will be cut off.

Publicidad

loading

Este manual también es adecuado para:

S-ls-114