4. CONTROLS
Key
Key Press
A
Short
Long press with all
loads off (motor and
lights)
B
Short
Long press with all
loads off (motor and
lights)
C
Short
D
Short
Long
E
Short
F
Short
5. LIGHTING
• Please contact the Service Depart-
ment to change it ("Please contact
Functions
Turns the motor on/off at the first speed.
The Filter saturation alarm is reset.
Signals the saturated Metal Grease Filters alarm and the need to
wash them. The alarm is activated after 100 hours of effective hood
operation.
Signals the Activated Carbon Odour Filter saturation alarm. The
alarm is activated after 200 hours of effective hood operation.
Signals the Metal Grease Filters saturation alarm and the Activ-
ated Carbon Odour Filter saturation alarm.
Decreases the operating speed.
Keypad Lock Function
Activates/deactivates the keypad lock for hood cleaning.
Increases the operating speed cyclically..:
1 - 2 - 3 - Intensive
Intensive: This speed is timed to 6 minutes. At the end of the time,
the system automatically returns to speed 3.
It is deactivated by decreasing the operating speed or by switching
off the motor.
Delay Function
Activates/Deactivates the Delay function, the automatic delayed
shut-down of the motor and lighting system after 30 minutes.
It is deactivated by pressing the same key or by switching off the
motor.
24h Function
It activates/deactivates the motor in 24h Air Exchange mode. This
function sets the motor to the first speed which allows suction with
an interval of 10 minutes on and 50 minutes off.
It is deactivated by pressing the same key or by switching off the
motor.
Turn the lights on/off at medium intensity.
Switches the lights on/off at maximum intensity.
the service department to purchase
it").
• Lamps in risk group 1 under IEC/
EN62471 at a distance of 20cm and
LED
LEDs A + B + C are
on.
The display shows
the set speed.
LEDs C + D flash 3
times.
With the motor off,
the display shows F
+ 1 multiple times
alternately.
With the motor off,
the display shows F
+ 2 multiple times
alternately.
The display shows F
+ 1 + F +2 several
times alternately.
On.
Flashes.
On/Off.
The display shows
an animation.
On/Off.
Flashes.
The display shows
an animation.
On/Off.
On/Off.
11