OPERATION PROCEDURE
Request:
To protect the compressor at the time of starting, turn on the power supply switch 12 hours before starting run.
Moreover, keep the power switch on in the season.
Be sure to leave the power supply switch of the indoor unit at the ON position even if the unit is not used. If any one of indoor
units belonging to the same line on the system is turned off, water may leak from the indoor unit (an overflow of drain water.)
REMOTE
COOL
I
FAN
1
SE T TEMP
HI
O
C
C
O
FAN
FILTER
TIMER
MODE
RESET
SPEED
TEMP
TIME
AUTO
SET
CHECK
SWING
3 4 5 2
Standard of room temp. setting
Cooling .......................... 26 to 28°C
Dehumidification ............ 21 to 24°C
Heating .......................... 22 to 24°C
Air blowing ..................... Room temp. set is not necessary.
G The Operation mode, temperature setting and blow rate can be changed during the operation stop as well. When they are
operated during stop, the corresponding display area is indicated for several seconds.
G After several seconds since the remote controller is operated, the setting of air-conditioner unit changes.
G To operate the air conditioner every day with repetition of run/stop under the same conditions (operation mode, set tempera-
ture, blow rate and auto swing), step 1 ON/OFF alone is sufficient.
The condition previously set is displayed on the remote controller.
NOTE
G Avoid frequent operation of "ON" and "OFF".
G When the cooling (dehumidification) and heating operation is selected, if the other indoor units are
operating in the different mode, the selected operating mode display flickers and the unit is operated in
the air blowing mode. Coordinate the operation mode. (The cooling/heating free multi-KXR unit can be
operated in different mode in the cooling and heating operation.)
G Do not use something with a sharp tip to press the remote controller switch.
G During raising and lowering of the setting temperature by pressing the temperature setting switch, the opera-
tion of unit may stop. This is caused from the activation of temperature controller and is not a malfunction.
G During the cooling (heating) operation, the unit may be operated with the cooling (heating) mode even if
the room temperature is lower (higher) than the setting temperature. This is not abnormal.
G The air blow rate in the dehumidification operation repeats "strong-weak- stop" in proportion to the room
temperature automatically. The adjustment by the blow rate switch is impossible.
G For the cooling/heating free multi-KXR unit, when the operation mode is changed from [cooling] to [heating]
or from [heating] to [cooling] during operation, the unit is operated in weak blow mode for 3 minutes.
G For the first operation after power on, when the room temperature is 17°C and above the unit automati-
cally starts cooling operation and when the room temperature is below 17°C it starts the heating opera-
tion. Set the operation mode and room temperature as you like.
G In the case of automatic operation the [cooling] and [heating] operation are changed over automatically in propor-
tion to the difference of setting temperature and the room temperature to keep the room temperature constant.
(For the cooling/heating free multi-KXR unit)
1
Press the "ON / OFF" switch.
The air conditioner starts operating.
2
To select an operation mode.
Press mode switch to change to "AUTO" ¡
"DRY" ¡ "COOL" ¡ "FAN" ¡ "HOT ".
3
Press the "ROOM TEMP." switch.
Press
or
to set the room temperature.
4
Press the "FAN SPEED" switch.
Fan speed varies in the following sequence.
HI
MED
LO
(In dehumidifying run, fan speed is automatically set.)
5
Press the "AUTO SWING" switch.
Effective stop position.
For COOL, DRY .......... Horizontal
For HEATING ............. Downward
Page 6
Stop
Press the "ON / OFF" switch.
Temperature
controller is
in operation.
H O T
COOL
PRESENT TIME SETTING PROCEDURE
G The timer is set based on the present time. Adjust the present time correctly at first.
1
2
REMOTE
COOL
I
FAN
SE T TEMP
HI
A M
O
C
O
C
FAN
FILTER
TIMER
MODE
RESET
SPEED
TEMP
TIME
AUTO
SET
CHECK
SWING
3
1
3,5
4
2,4,6
5
6
Press the timer switch.
The display changes with the following sequence:
No indication
Time indication
Timer ON
Program timer
Timer OFF
Set to [Time indication]
Press the setting switch.
The [Morning] indication flickers.
G In the case that the present time is in the morning, press
the setting switch again.
G In the case that the present time is in the afternoon, press
the time setting switch to change the indication of morning
to afternoon, then press the setting switch again.
Press the time setting switch.
The "hour" area is flickering.
Press the
or
to set "hour".
Press the setting switch.
The [hour] setting of present time has been finished.
Press the time setting switch.
The "minute" area is flickering.
Press the
or
to set "minute".
Press the setting switch.
The flickering of present time changes to continuous lighting
to indicate completion of setting.