AL03 IM_HO_L4
Plug the newly disconnected pipe using a clamp or
3
screw (check that the other end of the pipe is still
connected to the steel pipe welded in place 3)
Use the new supply blue pipe to connect the solenoid
5
valve (black sticker, first one near the threaded inlet)
to position 4 of the vapour exhaust pipe. Cut it to the
correct and "comfortable" length. Use the new screw
clamp to lock the hose in place.
Change Software parameters following documents:
7
-
"AL01 IM_HO_01_02_03_04" for Touch Oven
-
"AL02 IM_HO_01_02_03_04" for Digit Oven
Electrolux Skyline
Oven 06-10grids – Hood Level 4
Quenching modification procedure
4
6
Remove the screw in the inlet (position 4) of the
vapour exhaust pipe
Insert the new metal component supply from above
into the vapour exhaust pipe (pay attention to the
position of the side hole, at the bottom, as shown in
the picture below, axial orientation is irrelevant).
Rel.
210220