SETPOINTS CONFIGURATION
Setpoints configuration
SEtP
SEt1
SEt2
Counter mode ('Cont')
ModE
- 1 -
- 4 -
Hi
Lo
no
nc
PuLS
LAtC
01.0
SERIE KOSMOS
The third menu "SEtP" only appears when two relays output card is
installed. For further details on function modes please refer to the
corresponding OUTPUT OPTION part later on this manual.
Programming steps are similar for both relays on each "SEt1" and
"SEt2" submenus. The parameters to be configured are the following:
SETPOINT VALUE:
00.00:
Value entering in counts within available model display
range.
(Is not possible to change decimal point position, which is
the previously defined in display configuration menu).
CONTROL MODES (FOR SETPOINT 2 ONLY):
MODE 1:
INDEPENDENT
MODE 2:
STOP
MODE 3:
RESET
MODE 4:
CLEAR
ACTIVATING MODE:
Hi:
High level relay activation.
Lo:
Low level relay activation.
RESTING CONTACTS STATE:
no:
Normally open contact.
nc:
Normally closed contact.
PULSE OR LATCHED OUTPUT:
PuLS:
Pulse output with activation time configurable from 0.1 to
99.9s.
LAtC:
Latched output.