for selecting the material in MIG SYN / MIG PUL-
SE / ROOT WELDING by keeping holding it.
•
for navigating the Submenu
7
Left Regulation Knob
for adjusting the following welding parameters & values:
MMA/STICK - I2 Amp
GOUGING - I2 Amp
TIG - I2 Amp
MIG MAN - wire speed 1÷25 m/min
MIG SYN / MIG PULSE / ROOT WELDING
Amp, Wire Speed, Thickness 0,6÷25 mm
8
Navigation Key
for increasing the following welding parameters:
MMA/STICK - Arc Force
TIG - Post-Gas Time
MIG MAN - Inductance
MIG SYN / MIG PULSE / ROOT WELDING
Dynamics
9
Left Regulation Knob
for adjusting the following welding parameters & values:
MMA/STICK - I2 Amp
GOUGING - I2 Amp
TIG - I2 Amp
MIG MAN - wire speed 1÷25 m/min
MIG SYN / MIG PULSE / ROOT WELDING
Amp, Wire Speed, Thickness 0,6÷25 mm
10
Mode Key
for selecting the following welding processes:
MMA/STICK
GOUGING (only top model)
TIG
MIG MAN
MIG SYN
MIG PULSE (optional)
ROOT WELDING (Optional)
11
Selection Key
for selecting the following parameters in MIG/MAG
welding:
2 Stroke / 4Stroke
Spot Welding
Pause/Work
12
Right Regulation Knob
for adjusting the following welding parameters & values:
MMA/STICK - Hot Start
TIG - Down Slope
MIG MAN - Voltage (10-45V)
MIG SYN / MIG PULSE / ROOT WELDING
Voltage, Balance, Operation Point
13
Green LED
lights up when unit is working
14
Warning LED
lights up if the power source overheats (e.g. because
the duty cycle has been exceeded) or if there is a
problem on the water cooling. For more information
on this, see the "Troubleshooting" section.
15
Warning Red LED
lights up because of Over Voltage, Phase Loss, Max
I.out, Max P .out or if a generic problem occurrs.
EN-8
Left Display
16
views the welding parameters values.
Selection Key
16A
for selecting the following welding parameters:
MMA/STICK - I2 Amp
GOUGING - I2 Amp
TIG - I2 Amp
MIG MAN - wire speed 1÷25 m/min
MIG SYN / MIG PULSE / ROOT WELDING
Amp, Wire Speed, Thickness 0,6÷25 mm
16B
I2 Amp LED
lights up when the welding current parameter is selected.
16C
Wire Speed LED
lights up when the wire speed parameter is selected.
16D
Thickness LED
lights up when the thickness parameter is selected.
17
Right Display
views the welding parameters values.
17A
Selection Key
for selecting the following welding parameters:
MMA/STICK - Hot Start
TIG - Down Slope
MIG MAN - Voltage (10-45V)
MIG SYN / MIG PULSE / ROOT WELDING
Voltage, Balance
V2 LED
17B
lights up when the welding voltage parameter is selected.
Balance LED
17C
lights up when the balance parameter is selected.
P . LED
17D
lights up when the other parameters need to be
selected and adjusted, i.e. Hot Start in MMA/STICK,
Down Slope in TIG and Operation Point in MIG SYN
/ MIG PULSE / ROOT WELDING.
18
Setup Key / Material
for setting the following secondary parameters:
MMA/STICK - Arc Force
TIG - V2 CUT and Gas Time 0-25s
MIG MAN - Inductance 0-30
MIG SYN / MIG PULSE / ROOT WELDING
Dynamic -20% / +20%
19
Save & recall Key
for saving and recalling the working points that may
be changed by the operator.
BBT & Motor Slope Regulation Knobs
20
for setting the Burn Back Time and the Slope of the motor
in MIG/MAG. Note: knobs are located in the wire spool
compartment close to the wire feeding motor.