TROLLEY MOUNTING AND INSTALLATION
•
Follow the mounting instructions supplied with
the trolley to install the welding unit, compact
or with separate wire feeder and the cooling
unit.
HOSEPACK CONNECTION
•
Connect the dinse plugs of the interconnec-
ting hosepack to the Positive Sockets -
the back side of wire feeder and power gene-
rator.
•
Connect the military connectors of the inter-
connecting hosepack to the Sockets -
the back side of wire feeder and power gene-
rator.
•
Connect the blue water feed hose of the in-
terconnecting hosepack to the connections
marked in blue -
feeder and water cooler.
•
Connect the red water feed hose of the in-
terconnecting hosepack to the connections
marked in red -
feeder and water cooler.
WATER COOLER CONNECTION
Important: read also the Operating instruc-
tions supplied with the water cooler before
connecting it to the welding unit.
For Compact Units:
•
Remove the covering metal plate from the
back panel of the unit -
•
Refer to the Assembly Paragraph for the unit's
installation, for the connection of the hose-
pack and of the water cooler (if present).
•
Load the wire, connect the gas cylinder and
replace the wire liner if necessary following
the instructions in this paragraph.
•
Check line voltage and connect power cable.
•
Control the amount of the cooling liquid in
the water coller and power it ON.
•
Power the welding unit ON. The display shows
the screen of the last welding process perfor-
med by the unit.
•
Check the activation of the cooler unit on Ini-
tial Setup Menu before proceeding.
WIRE LOADING
Figure 12 - Spool Assembly
EN-10
ASSEMBLY
- on the back side of wire
Q
- on the back side of wire
Q
-.
U
PREPARATION FOR WELDING
•
Connect through the quick connectors the
power cable and the pressostat cable of the
water cooling unit to the welding unit.
•
Fix the metal plate assembled to the power
and pressostat cables to the back panel of the
unit.
For Power Units with Separate Wire Feeder
•
Locate the plate for the water cooler connec-
tion inside the generator, on the bottom back
left side.
- on
L
•
Thread the two cables, the power cable and
the pressostat cable, through the holes on the
bottom panel of the unit and connect them as
shown in the label affixed close to the con-
- on
J
nection plate.
Figure 11 - Water Cooler Connection Plate
Important: The water cooler is activated
from the menu "Basic Setup". Refer to "Ba-
sic Setup" section.
Ensure the gas and electrical supplies
are disconnected. Before proceeding,
remove the nozzle and the contact tip
from the torch.
•
Open the side panel.
•
Loosen the nut of the spool holder (brake
drum). In the case you are replacing the wire
spool, extract it.
•
Remove the plastic protection from the spool.
Place it on the spool holder. Tighten the lock
nut turning it.
The unit can also accept 100 mm dia-
meter wire spools. For the mounting
follow these instructions:
•
Remove the wire spool from the spool holder.
•
Loosen the nut, mount the new spool and the
washers as shown in the picture 12.
•
Tighten the lock nut.
Tighten nut (A) to appropriate tightness.
Excessive pressure strains the wire fee-
ding motor. Too little pressure does not
allow the proper wire feeding.
PS
PS
L
L
1
2
PRESSOSTAT