is produced
(service repair)
The compressor
does not start.
The "WATER
LOW" indicator
is on.
The "FAULT"
light flashes
every second.
The "FAULT"
light flashes
every 5 seconds.
The "FAULT"
light is on
continuously.
WIRING DIAGRAM
b)
Clogged refrigerant fan
compressor.
c)
Electrovalve stuck
open.
d)
Defective fan.
e)
Hall sensor defective.
a)
No water in the
system.
b)
Full ice container.
c)
The compressor stops
(overheating of the
outside of the
compressor).
a)
No water in the inlet.
b)
Water valve defective.
c)
Water pressure in the
water connection is
too low.
a)
Temperature sensor
defective.
a)
The water mixer
sensor does not work.
a)
Problem with the
refrigerant system.
b)
Fill the system with
nitrogen (N
check if it is blocked
and replace the filter
(dryer).
c)
Replace the solenoid.
d)
Check the Hall sensor.
a)
Check the water
connection (supply hose
and water inlet valve).
b)
Empty the ice from the
container.
c)
Turn off the unit and
after approx. 1 hour
turn it off again.
a)
Check the running
water connection and
restart the unit.
b)
Check the water valve.
c)
Check the pressure in
the water connection.
a)
Replace the
temperature sensor.
a)
Check the connection to
the water mixer sensor.
a)
Check the cooling
system.