Z o n e V a l v e 1
L
N
W i r i n g C e n t r e
MAIN SUPPLY UFH
L
D i a l
s t a t
S L
1 2
1 3
S L
Z o n e V a l v e
1 0
1 1
1 2
1 3
N
H e a t S o u r c e
C H
C
S L
U F H
BOILER
P E
N
S L
C H
Z o n e V a l v e 1
L
N
C
U F H
W i r i n g C e n t r e
MAIN SUPPLY UFH
L
P E
N
C
N
L
U F H
S L
C
U F H
Z o n e V a l v e
L
N
L
H e a t S o u r c e
WIRING DIAGRAM LEGEND
Note: If a UFH zone valve is not required or if it is connected directly to the
UFH wiring centre, then the wiring connection from boiler SL on the wiring
centre would go into terminal 13, instead of terminal 9.
WIRING DIAGRAM LEGEND
S L
Note: If a UFH zone valve is not required or if it is connected directly to the
UFH wiring centre, then the wiring connection from boiler SL on the wiring
centre would go into terminal 13, instead of terminal 9.
BOILER
S L
The world's best-selling floor heating brand ™
WARMUP PLC, 702 & 704 Tudor Estate, Abbey Road, London, NW10 7UW
TITTLE
Wiring Diagram
S Plan+_UFH
DATE
08.02.2017
N
L
PDF FILE
Warmup - WD - S Plan+_UFH - 2017-02-08.pdf
The world's best-selling floor heating brand ™
Any electrical works undertaken should be completed by a suitable
WARMUP PLC, 702 & 704 Tudor Estate, Abbey Road, London, NW10 7UW
qualified competent electrician.
Any interconnecting electrical components that form part of a hydronic
system should be connected to a 3A power supply, with the whole
system having a single point of isolation.
TITTLE
Wiring Diagram
The Warmup word and associated logos are trade marks. © Warmup
Plc. 2010 - Regd. TM Nos. 1257757, 4409926, 5265707. E & OE. Registered
S Plan+_UFH
in England No. 2955213.
DATE
08.02.2017
PDF FILE
Warmup - WD - S Plan+_UFH - 2017-02-08.pdf
Any electrical works undertaken should be completed by a suitable
qualified competent electrician.
Any interconnecting electrical components that form part of a hydronic
system should be connected to a 3A power supply, with the whole
system having a single point of isolation.
The Warmup word and associated logos are trade marks. © Warmup
Plc. 2010 - Regd. TM Nos. 1257757, 4409926, 5265707. E & OE. Registered
in England No. 2955213.
Live
Earth
Neutral
Switched Live
Switched Live
Common
Hot Water
Central Heating
Live
Earth
Neutral
Switched Live
Switched Live
Common
Hot Water
Central Heating
Tel 0345 034 2288 Fax 0203 453 2299
support@warmup.com www.warmup.co.uk
DRAWN
GW
Tel 0345 034 2288 Fax 0203 453 2299
support@warmup.com www.warmup.co.uk
DRAWN
GW
L
E
N
SL
SL
C
HW
CH
L
E
N
SL
SL
C
HW
CH