ERV output
Mode 26
CNER input
Setting No.
OFF
ON
1
Factory setting
2
The G/Y1 signal to the furnace is energized to turn on the furnace blower. If kumo cloud
used and configured to operate a second stage blower speed, the Y/Y2 signal is also energized.
15.10.1. Heat recovery ventilation (HRV)
PAA unit heating model operation in a system that includes HRV
The ported MXZ outdoor units continue to circulate hot gas through the PAA unit in thermal off. HRVs
may require the operation of the furnace blower in conjunction with the HRV when their fan is not powerful
enough to circulate the air throughout the house. The furnace blower operating while in thermal off mode
will cause the PAA unit to release a large amount of heat in the air flow.
The branch box MXZ continues to circulate a smaller amount of hot gas through the PAA unit in thermal off
in comparison to the ported MXZ outdoor units.
Specifications are subject to change without notice.
PAA-A18, 24, 30, 36, 42AA1/BA1/CA1
Condition
Cool/Heat/Fan
operation
-
Defrost
STOP
Cool/Heat/Fan
operation
Defrost
STOP
Cool/Heat/Fan
operation
2
Defrost
STOP
95
Furnace blower
CN2C output
(expected op-
(expected fur-
eration)
nace blower
output)
ON²
ON
STOP
OFF
STOP
OFF
ON²
ON
STOP
OFF
STOP
OFF
ON²
ON
STOP
OFF
ON²
ON
®
app is