Troubleshooting:
Error
Machine not ready to use, no display in the
touch panel
Heater does not start
Pressure cylinder does not,
or incompletely extend
Pressure cylinder does not seal (blowing sound)
Program reacts absurdly
Absurd temperature indication
Adaptation not sufficient
Note (only Track
-P-ci):
®
When processing thin flexible foils, holes may
form in the foil. If the pressure drops below 1.5
bar, this will be displayed.
Do not interrupt the thermoforming process! A
good thermoforming result is most likely.
Possible cause
Power supply defective, room temperature
below 15 °
Foil reception not locked under the heating
• Protection shield not extended
• Form pot is not in the rearmost position
• Not enough pressure (Track
P)
®
• Worn sealings
• Not enough pressure (Track
P)
®
System crash
• Sensor window soiledt
• Draught disturbs the sensor, sensor defective
• Granules on sealings
• Sealings used
• Hole in the foil
• System pressure too low
Display pressure loss:
Possible elimination
Check wall socket, machine plug, fuses,
operating temperature > 15 °C.
Check position of the foil reception.
• Foil reception must be in the rearmost, locked
position, or CS (Customer Service).
• Push form pot with model backwards into the
unit until it clicks into place.
• System pressure at least 6 bar, pressure line
with min. 6 mm inner diameter, without creases.
• Replace sealings.
• System pressure at least 6 bar, pressure line
with min. 6 mm inner diameter, without creases.
Restart, switch machine off for 30 sec. and
switch on again.
• Clean sensor window.
• Avoid draught near the unit, if necessary
CS sensor check.
• Remove granules from the sealings.
• Replace sealings.
• Remove the sharp edges on the model, embed
the model deeper, if necessary choose thicker
foil material.
• System pressure at least 6 bar, pressure line
with min. 6 mm inner diameter, without creases.