Descargar Imprimir esta página

Intellinet Network Solutions 508834 Manual De Instrucciones página 3

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 6
1
Power Off Alarm
You can choose whether to connect the power failure warning device to the
connecting terminal marked "Fault" according to your requirements. When using
power redundancy, if one power source fails, a fault alarm will be generated.
Chassis Ground Column
Located on the side of the power supply connector, a grounding terminal connector is used
to provide proper grounding for your Intellinet Network Solutions switch. If you use the
chassis grounding screw, it should be wired to an object that provides earth ground.
Placement
Desktop Installation
Prior to use, place/position the switch:
• on a level surface that can support the weight of the switch and that offers
at least 25 mm (approx. 1") of clearance for ventilation;
• away from sources of electrical noise: radios, transmitters, broadband amplifiers;
• within 100 m (approx. 328') of network devices it's to be connected to.
DIN-Rail Installation
1 With DIN-rail bracket attached to device with screws, angle bracket onto DIN rail.
2 Push device in till it clicks into place.
Basic Web-Based Browser Management
1 Open your Web browser.
2 Enter http:// and the IP address of the switch in the Address field.
The default management IP address is 192.168.2.1.
3 Press Enter to display the login screen. In the Username field, enter admin; in the
Password field, enter the serial number on the bottom of the switch. Click OK.
2
1
3
2
Instructions
4
3
English

Publicidad

loading

Este manual también es adecuado para:

Iis-8g02m