The MENU | CONTROL | Cooling for several days
function is activated.
–
The competent person has activated the MENU |
SETTINGS | Installer level | Installation configur-
ation | Installation | Automatic cooling: function.
The function automatically switches between heating
and cooling mode. The function has enabled cooling
mode.
–
The competent person has defined the Ext. cooling
mode in the MENU | SETTINGS | Installer level | In-
stallation configuration | HP control module con-
figuration | MI: function. A signal from an external
control switches between heating and cooling mode.
As long as a signal is present, cooling mode is active.
2.9
What is meant by "time period"?
Example of heating mode in the mode: Time-controlled
B
24 °C
21 °C
1
16 °C
5
16:30
18:00
A
Time
B
Temperature
1
Time period 1
2
Time period 2
You can divide a day up into several time periods (1) and (2).
Each time period can comprise an individual start time and
end time. The time periods must not overlap. You can assign
a different desired temperature (3) to each time period.
Example:
16:30 to 18:00; 21 °C
20:00 to 22:30; 24 °C
The living rooms are heated to the desired temperature
within the time periods. In the times outside of the time
periods (5), the living rooms are heated to the lower set-back
temperature (4) that is set.
Example of cooling mode in the mode: Time-controlled
0020287900_03 Operating and installation instructions
3
2
4
5
5
20:00
22:30
3
Desired temperature
4
Set-back temperature
5
Outside of the time
periods
B
24 °C
4
16:30
A
Time
B
Temperature
1
Time period 1
You can divide a day up into several time periods (1) and (2).
Each time period can comprise an individual start time and
end time. The time periods must not overlap. You can set a
desired temperature (3) that is assigned to all time periods.
Example:
16:30 to 18:00; 24 °C
20:00 to 22:30; 24 °C
The living rooms are cooled to the desired temperature
within the time periods. During the times outside of the time
A
periods (4), the living rooms are not cooled.
2.10
What is the effect of the hybrid manager?
The hybrid manager calculates whether the heat pump or
the additional boiler covers the heat demand cost-effectively.
The decision-making criteria are the set tariffs in relation to
the heat demand.
To ensure that the heat pump and the additional boiler can
work effectively, you must enter the tariffs correctly. See
MENU | SETTINGS. Otherwise, increases costs may arise.
2.11
Preventing malfunctions
▶
Do not cover the system control with furniture, curtains or
other objects.
▶
If the system control is installed in the living room, open
all of the thermostatic radiator valves in this room fully.
1
2
4
20:00
22:30
18:00
2
Time period 2
3
Desired temperature
4
Outside of the time
periods
3
4
A
61