To install the heat pump only the hydraulic circuit and the power need to be
connected.
3.1
Location
The heat pump must be installed at least 2.5 m away from the pool.
Please respect the following rules when choosing the heat pump's installation location
1.
The location must be easily accessible for optimal operation and maintenance.
2.
The device must be installed on the ground, ideally on a level concrete slab. Ensure that
the ground is sufficiently stable and it can support the weight of the device.
3.
Check that there is enough air flow, that the air exhaust is not directed towards the
windows of neighbouring buildings, and that exhaust air cannot return to the intake. In
addition, ensure that there is enough space around the device to perform servicing and
maintenance.
4.
The device must not be installed in locations susceptible of being exposed to oil, flamma-
ble gas, corrosive agents, sulphur compounds, or near high frequency devices.
5.
Do not install the device near to roads or footpaths to avoid mud splattering.
6.
To avoid disturbing neighbours, make sure to install the device facing away from areas
sensitive to noise.
7.
Keep out of the reach of children insofar as possible.
≥ 1500
Do not place anything within 1.5m of the front of the heat pump.
Leave at least 30cm of empty space to the sides and rear of the heat pump.
Do not place any obstacles on top or in front of the device!
3. Installation
>2.5m
≥ 1500
SPA
≥ 300
≥ 1500
Dimensions in mm
EN
| 11