Operation
Use conditions
For the heat pump to operate normally, the ambient air temperature must be between 10°C
and 43°C when it is used alone or between -7°C and 10°C when used with the SPA heater.
Advance notice
Prior to starting the heat pump, please:
Check that the equipment is in a stable position.
Check that your electrical installation is in good working condition.
Check that the hydraulic connections are properly tightened and there is no water leakage.
Remove any object that is not required around the equipment and all tools.
Operation
1. Connect the power supply to the device.
2. Start the filtration pump.
3. Activate the device's electrical supply protection (differential switch situated on the power
cable).
4. Start the heat pump.
5. Select the desired temperature using one of the modes appearing on the control panel.
6. The heat pump's compressor will start shortly after.
And you just need to wait for the target temperature to be reached.
WARNING: Under normal conditions, a suitable heat pump can heat up the tub water
by 1°C to 2°C per hour. It is therefore normal that you do not feel any difference in
temperature at the outlet level when the heat pump is on.
A heated tub must be covered and insulated to avoir any heat loss.
Good to know: restart after power failure
After a power failure or a usual interruption, turn the power back on, the system is on sleep mode.
Restart the differential plus and switch on the heat pump.