4.6
Using the circulation pump control relay (optional)
Poolex Relay
240VAC 30A
125VAC 30A
250VAC 15A cos Ø = 0.4
This relay is controlled by the heat pump control box either automatically or manually.
As such, for the system to function correctly, it is imperative to have a circulation pump which
minimum flow ranges from 1.2 m³/h to 3 m³/h (to be determined according to the pump selected).
In automatic mode: The relay activates itself every 60 minutes (timing adjustable between 30
and 90 minutes, C31 setting) to control the circulation pump whilst temperature is being verified. If
needed, the controller starts the heat pump to reach the target temperature while the pump relay
remains active up until the target temperature is reached, then will start its verification cycle every
60 minutes (timing adjustable between 30 and 90 minutes, C31 setting).
In manual mode: The pump relay will always be active and the pump will function 24/7.
To use this relay:
Setting the C30 setting = 1 to start the control (see advanced settings).
Adjusting verification time intervals, C31 setting, if necessary (adjustable from 30 to 90 minutes).
When the heating pump is switched off (OFF): press on
manual mode and vice versa.
In automatic mode, the pump indicator is fixed. In manual mode, the pump indicator flashes.
4. Use
*
Insulate the connectors inside the spa in a
waterproof connection box
(
*
elements not provided)
Terminal block 11
*
to switch from the automatic to the
Circulation
pump
EN
| 17