Technical Data
Description of the
Parameter
Product name
Model
Supply voltage [V~] /
Frequency [Hz]
Electricity
Rated power [W].
Safety class
IP code
Dimensions [Width x Depth x
Height; mm]
Weight [kg]
Time range [min]
Temperature range[°C]
Maximum curing area [mm]
Application conditions
Value of the
INFRARED PAINT DRYER
MSW-IPD-2000-2W
800 x 1010 x 2490
41.4
* The temperature depends on the setting and
distance of the radiator from the surface to be
800 x 1000
Ambient temp. 5~+40
Humidity 20~95%
Parameter
MSW-IPD-2000-2H
230/50
1-phase
2 x 1000
I
IP32
500 x 580 x 1600
0-60
0-100
treated.
1200 x 1000
21
o
C