Descargar Imprimir esta página

EAS ELECTRIC EPMV2 Serie Manual De Instrucciones página 73

Publicidad

Idiomas disponibles

Idiomas disponibles

c. Strip the insulation from the ends.
d.
Using a wire crimper, crimp u-lugs on the
ends.
NOTE: When connecting the wires, strictly
follow the wiring diagram found inside the
electrical box cover.
2. Remove the electric cover of the outdoor unit.
If there is no cover on the outdoor unit, take
o the bolts from the maintenance board
and remove the protection board.
3. Connect the u-lugs to the terminals
Match the wire colors/labels with the labels
on the terminal block. Firmly screw the u-lug
of each wire to its corresponding terminal.
4. Clamp down the cable with the cable clamp.
5. Insulate unused wires with electrical tape.
Keep them away from any electrical or metal
parts.
6. Reinstall the cover of the electric control box.
Indoor Unit Wiring
1. Prepare the cable for connection
a. Using wire strippers, strip the rubber jacket
from both ends of the signal cable to reveal
about 15cm (5.9") of the wire.
b. Strip the insulation from the ends of the wires.
c. Using a wire crimper, crimp the u-lugs to
the ends of the wires.
2. Pull the left and right handles of the front panel ,
pull the panel outward, and open the panel.
3. Remove the electric control box.
Connect the u-lugs to the terminals.
Match the wire colors/labels with the labels on
the terminal block, Firmly screw the u-lug of
each wire to its corresponding terminal. Refer
to the Serial Number and Wiring Diagram
located on the cover of the electric control box.
Cover
Screw
This wires is just
for test.Please remove
while installation.
NOTE: When taking out the electric control box,
pay attention to loosen and remove the terminal.
Magnetic ring
accessories)
Illustrations in this manual are for
explanatory purposes. The actual shape
shall prevail.
While connecting the wires, please
strictly follow the wiring diagram.
The refrigerant circuit can become very hot.
Keep the interconnection cable away from
the copper tube.
5.
4. Clamp down cable with the designated cable
clamp to secure it in place. The cable should
not be loose, and should not pull on the u-lugs.
Reinstall the electric box cover and the front
panel of the indoor unit.
35
(if supplied and packed with the
Pass the belt through
the hole of the Magnetic
ring to fix it on the cable
CAUTION
Electric control box
Wiring diagram
V.4

Publicidad

loading