MAINTENANCE
To Add Oil
• Position the jack on level ground and lower the saddle. Remove the Breathing Screw.
• Fill the oil case until oil level is just beneath the lower rim of oil fill hole. Replace Breathing Screw.
• Perform the Air Purge Procedure described below.
To Replace Oil
• Fully open release valve by turning handle counterclockwise as far as it will go.
• Turn the jack over so that old oil will drain from the oil fill hole.
• Refill through oil fill hole. Keep dirt and other material clear when pouring. Fill to just beneath lower
rim of hole. Replace Breathing Screw.
• Perform Air Purge Procedure described below.
Lubrication
• Add lubricating oil (WD-40) to all moving parts when needed.
• For light duty use lubricate every six months.
• For heavy and constant use lubrication recommended every month.
Rust Prevention
• Check ram and pump plunger on the Power Unit Assembly every two months (or sooner, based on
usage) for any signs of rust or corrosion. Lift the jack as high as it goes and look under and behind
the lifting arm.
If signs of rust are visible clean as needed and wipe down with an oily cloth or e.g. WD-40.
• When storing the jack, always have the saddle and pump plunger in the down position.
Always use a good grade hydraulic jack oil. Do not use hydraulic brake fluid, alcohol, glycerine,
detergent, motor oil or dirty oil. Use of an un-recommended fluid can cause damage to your jack.