Thermotronik T77
9 Menu Sequence Overview
Main menu
Submenu 1
Configuration
t___
Equipment configuration
Display
____
____
Measurement display
Temperature
____
Out 1
tEMP
Temperature main menu
Settings menu OUT1
Out x
Settings menu OUTx
Analog Out1
Settings menu Analog 1
Exit
Exit menu level
b. E F
Basic EF
Reset
Factory setting
Basic Adv. Functions
Set error handling
Error handling
Set Unit Temp
Temperature unit
Cable Length
Pt100 lead length
Cable Cross
Pt100 cable cross-section
reassign O1
Set Out 1
reassign O2
Set Out 2
Display Rate
Display rate
Lock Device
Keylock
Exit
Exit menu level
Diagnostic
diA
Journal Out
Diagnostics menu
Log output
Max/Min Temp
Max/Min memory
Set Journal Out
Output monitoring
Delay MM
Min/Max Delay
Exit
Exit menu level
E
Exit
Exit menu level
12
Bühler Technologies GmbH
Submenu 2
Submenu 3
Shortcut
+
or 60s no action:
Exit main/submenu
out1
____
SP1
____
____
FH1
F1. H i
Switching point 1
____
rP1
FL1
F1. L o
____
Switch-back point 1
____
EF 1
EF1
Delay SP 1
Extended functions
Delay OUT1 On
Delay RP 1
Delay OUT1 Off
Set Out 1
Definition OUT1
Check Out 1
Functional test OUT1
LED Out 1
Function status LED1
Exit
Exit menu level
Exit
E
____
Exit menu level
____
out_
See menu structure Out1
Not applicable for version with
analogue output
____
____
An1
Analog Max1
A1. H i
Set maximum value
____
Analog Min1
A1. L o
Set minimum value
____
Set A.Out1
A. o u1
Output function
Check An1
C. A n1
____
Functional test Analog 1
E
____
Exit
Exit menu level
E
rES
Err. h
t. u ni
t. C L
Alternate menu
for version with wall mount
Not used when ordered with attached
t. C S
r. o u 1
r. o u 2
di5
Loc
E
J. o ut
t. M M
SJ. o u
dt. M M
E
Settings and Display Menu
Selection menu
____
____
SP1
0°C - 100°C
FI. H i
Selection menu
____
____
rP1
FI. L o
0°C - 100°C
____
____
dS1
Selection menu
___
Amount of time the signal must be present for output OUT1 to trigger.
Setting range: 0...100 seconds (for frequency output without function)
0 - 100
____
Selection menu
____
dr1
___
Amount of time the signal must be present for output OUT1 to switch back.
0 - 100
Setting range: 0...100 seconds (for frequency output without function)
Definition of switching characteristics for output 1:
____
____
ou1
Selection menu
___
Hno Hnc Hysteresis function NO contact or NC contact
Hno - FM
Fno Fnc Window function NO contact or NC contact /
n. o P
____
Selection menu
____
C. o u1
____
oFF
n. o p - on
on
____
____
LEd1
Selection menu
L=__
L= o
L= o - L=-o
L=-o
____
E
Selection menu
____
____
Sets the maximum analogue output signal to a defined value.
(Note: Max. – Min >= 10 % of the measuring range)
0°C - 100°C
____
Selection menu
____
Sets the maximum analogue output signal to a defined value.
0°C - 100°C
(Note: Max. – Min >= 10 % of the measuring range)
Selection menu
____
_ _
Selecting the analogue output function:
i I
i 1 - u 3
Selection menu
____
____
n. o P
n. o P - Lo
HALF
Alternate menu for version with analogue output
Not applicable when ordered with 2 or more
switching outputs
Confirm
____
___
Resets the device to delivery status
no - YES
____
Selection menu
___
Disable/enable normal error handling and analysis
; n o - YES
____
Selection menu
Selecting the temperature unit displayed:
°_
°C [Celsius],
°C - °F
____
Selection menu
__M
Pt100 line length in metres (supply line length x number of conductors), for compensating
0M - 20m
the supply line resistance. ΔT [Δ°C] = 0.462 [Δ°C] x length [m] / cross-section [mm²]
____
detector
Selection menu
_. _ _(
Pt100 line cross-section in millimetres , for compensating the supply line resistance
0. 2 5( - 1. 5 (
____
Selection menu
____
Set switching output Out 1 to function or to error signal
tEMP - Err
Selection menu
____
____
Set switching output Out 2 to function or to error signal
tEMP -Err
____
Selection menu
____
Selecting the display refresh rate:
FASt - off
FASt [fast], Medi [medium], SLo [slow],
____
Selection menu
___
Activating the keylock by entering a numerical code > 0 Master code 287
0 - 999
____
Selection menu
____
Displays the last 6 alarms + delete function.
Jor I - ---
Display:
____
Displays limits + delete function.
Selection menu
____
Display: Value – amount of time passed in hours/days; scroll through journal with ▲▼
____ - ---
____
Selection menu
out_
Selecting the alarm output to be logged
Out1 - Out_
____
Selection menu
___
Amount of time the signal must be present before saving the maximum / minimum value.
0 - 100
Setting range: 0...100 seconds
Setting the switching point /
FH1 Define maximum window limit
Sets a value for frequency 100 Hz (only OUT1 and OUT2)
Set switch-back point /
FL1 Set lower window limit
Sets a value for frequency 1 Hz (only OUT1 and OUT2)
FM
Normal switching output operation
Switching output Off /
F1
Simulation 1 Hz
F100
Simulation 100 Hz
Switching output On /
LED = output: follows switching output
LED = -output: inverted to switching output
4...20 mA
u 1
2...10 V
u 2 0...10 V
u 3 0...5 V
Analogue output normal mode /
Hi Output maximum analogue value
Output mean analogue value /
Lo Minimum analogue value output
°F [Fahrenheit]
2
oFF [Display off]
JorX
X – amount of time passed in hours/days; scroll through journal with ▲▼
Frequency output 1-100 Hz