EN
Thank you for purchasing our combination smoke and CO alarm device. Please
read this manual carefully to ensure proper use and store it in a safe place for future
reference.
Product specifications
Power: 3VDC
Battery Package: CR123A, Lithium Battery,1600mAh(Included)
Operation Current: <30uA (standby); <70mA (alarm)
Alarm Volume: >85 dB(A) at 3 meters
Smoke Sensitivity: 0.09 - 0.17 dB/m
CO sensor: Electrochemical sensor
CO Sensitivity: 50ppm
100ppm
300ppm
Operating Temperature: -10°C to 40°C
Humidity Range: 15%-95% R.H.(Non-condensing)
Silence Time: Approx. 10 minutes
Complies to Standard EN14604:2005/AC:2008(Smoke) and EN50291-1:2018(CO)
Packing list
1 × Combination smoke and CO detector
1 × Mounting bracket
1 × Screw kit
1 × User manual
Installation instructions
• Check figure 1, 2 and 3 for correct installation locations.
• Smoke, heat and burning things will spread horizontally after rising to the ceiling, so install
60~90min
10~40min
1~3min