3. Specifications
Cable outlet, shielded
EN
Wire cross-section 3 x 0.14 mm²
Cable diameter 4.3 mm
Cable length 2 m
3.9 Cleanliness specifications
Level of cleanliness
Breathing gas
Residual hydrocarbons
Medical standard
Residual hydrocarbons
Particle size
Industrial standard
Residual hydrocarbons
High industrial standard
Residual hydrocarbons
3.10 Packaging
Level of cleanliness
Breathing gas
Medical standard
Industrial standard
High industrial standard
12
2-wire
brown
U
B
0V
blue
-
+
S
Measuring range < 30 bar [435 psi]
Oil and grease free
< 1,000 mg/m²
per ISO 15001
< 550 mg/m²
not applicable
Oil and grease free for oxygen per ASTM G93
level D/E
< 550 mg/m²
Oil and grease free for oxygen per
ASTM G93 level C
< 66 mg/m²
Type of packaging
Protection cap on the process connection
Protection cap on the process connection, instrument sealed in a plastic bag
Option: Protection cap on the process connection, instrument sealed in two
plastic bags
3-wire
brown
blue
black
Measuring range > 30 bar [435 psi]
Oil and grease free
< 1,000 mg/m²
per ISO 15001
< 220 mg/m²
on request
Oil and grease free for oxygen per ASTM G93
level D/E
< 220 mg/m²
Oil and grease free for oxygen per ASTM G93
level C
< 66 mg/m²
WIKA operating instructions, model MG-1