WARNINGS
Your PRODUCT's NAME has many features
that will make your job faster and easier.
Safety, performance and reliability have
been given top priority in the design of this
tool, qualities to make easy to maintain and
to operate.
1. Read all safety instructions and safety ti-
pis before using this product, failure to do
so may result in personal injury.
2. This product is for the cleaning of small
mechanical parts, motors, etc...
3. Keep away from children, do not let chil-
dren operate this machinery.
4. Do not use this product other than what
is specified in the instruction manual.
5. Keep work area clean and well lit. Wear
proper protective clothing and safety gog-
gles to prevent injury.
6. Do not use near open flame or spark. Do
not use in the presence of flammable gas
or liquids.
7. Guard against electric shock. Do not
pinch power cord. Do not unplug by pulling
on cord.
8. Drain compressor and unplug unit when
not in use.
9. Use common sense when operating ma-
chinery, Urrea Herramientas is not respon-
sible for injury due to improper use.
10. For indoor use only.
SAVE THESE INSTRUCTIONS.
ELECTRIC SAFETY
Double insulation eliminates the need for
the three wire grounded power cord and
grounded power supply system.
Do not abuse of the power cord. Never use
the power cord to carry the tool and do not
pull the plug off the outlet. Keep the cable
away of heat, oil, sharp edges or moving
parts. Replace damaged cords immediately.
Damaged cords increase the risk of electric
shock.
4
INSTRUCTIONS
1. Before assembling parts, please check the
parts quantity according to the PARTS LIST.
2. Carefully unpack and spread out all parts
in a large uncluttered area.
3. Familiarize yourself with all parts and
compare them with the drawing below to
make sure none are missing.
CONTENT
2
4
6
1. Lid
2. Lid arm
3. Flexible metal hose
4. Removable Work Shelf
5. Power Cord
6. Pump
OPERATION
1. Fill unit with water-based solvent just
below the level of the parts shelf before
plugging into the electrical outlet.
2. Carefully follow degreaser manufactur-
er's instructions.
3. Open top lid and place parts on remov-
able tray (maximum load capacity is 66 lb).
4. Position the adjustable nozzle over the
parts.
5. Turn the power switch to the ON position.
6. Clean parts as needed.
7. When finished, turn switch to OFF posi-
tion.
8. Clean up work station.
9. Fusible link must be replaced if triggered.
1
3
5

Publicidad