OPTIONAL BLOWER: MODEL PBAR-2427,
120 VOLTS, 60Hz, 1.0 AMPS, 2900 RPM
DANGER: RISK OF ELECTRIC SHOCK.
DISCONNECT POWER BEFORE SERVICING UNIT.
IMPORTANT: FOR OPTIMUM HEATER
PERFORMANCE AT LOW BURN RATE, OPERATE
THE FAN AT LOW SPEED.
For installation information on optional blower PBAR-2427,
please refer to the Wood Stove Blower Installation and
Operating Instructions supplied with the blower.
MOBILE HOME APPROVED
This appliance, excluding Model # WS-2417 is approved
for mobile home installations when not installed in a sleep-
ing room and when an outside combustion air inlet is pro-
vided. The structural integrity of the mobile home floor,
ceiling, and walls must be maintained. The appliance must
be properly grounded to the frame of the mobile home and
use only listed double-wall connector pipe. An Outside Air
Kit must be installed in a mobile home installation.
NOTE: This installation must conform with local
codes. In the absence of local codes you must comply
with the UL1482, (UM) 84-HUD and NPFA211 in the
U.S.A. and the CAN/ULC-S629 and CAN/CSA-B365
Installation Codes in Canada.
OUTSIDE AIR KIT INSTALLATION
A source of air (oxygen) is necessary in order for com-
bustion to take place. Whatever combustion air is con-
sumed by the fire must be replaced. Air is replaced via
air leakage around windows and under doors. In homes
that have tightly sealed doors and windows, an outside
air source is needed.
Items Needed for Installation
• Pipe clamp, termination cap, (2) wire ties, and fasteners
• 4 inch flex aluminum pipe, or if using alternate mate-
rial, then it shall be made from durable, non-combustible,
heat resistant material up to 350°F. Cut the pipe to the
required length for your installation.
Figure 00
• Electric screw driver with bits
• Silicone sealant
• Drills and saws necessary for cutting holes through
the wall or flooring in your home
AN OUTSIDE AIR KIT (ITEM NO: OAK-MH) IS
AVAILABLE FOR PURCHASE BY CALLING GHP
GROUP CUSTOMER SERVICE AT 1-877-447-4768.
1. Remove all materials from packing boxes.
2. Floor & Rear Installation: Cut a 4 inch (102mm) hole
in outside wall or floor to accommodate outside air pip-
ing. Use 4 inch (102mm) aluminum metal flex or rigid
piping to directly connect outside air to appliance intake.
Use a termination cap with a rodent screen. Seal
between the wall (or floor) and the pipe with silicone to
prevent moisture penetration.
3. Using a #2 Phillips screw driver attach the flex pipe to
the flex adaptor on the stove using a pipe clamp.
Figure 00.
Fire Risk.
Asphyxiation Risk.
Do not draw outside combustion air from:
• Wall, floor, or ceiling cavity
• Enclosed space such as an attic or garage
• Close proximity to exhaust vents or chimneys
Fumes or odors may result
Asphyxiation Risk.
Outside air inlet must be located to prevent
blockage from:
• Leaves
• Snow or ice
• Other debris
Block may cause combustion air starvation.
Smoke spillage may set off alarms or irritate
sensitive individuals.
Asphyxiation Risk.
Length of outside air supply duct shall NOT
exceed the length of the vertical height of the
exhaust flue.
• Fire will not burn properly.
• Smoke spillage occurs when door is open due
to air starvation.
2
WARNING
WARNING
WARNING