Maintenance - SATA jet 5000 B Instrucciones De Servicio

Ocultar thumbs Ver también para jet 5000 B:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 133
Operating instructions SATAjet 5000 B RP/HVLP (DIGITAL)
• Do not clean cover plate of the electronic pressure display with
pointed, sharp or rough objects!
• Drillings are to be cleaned with SATA cleaning brushes or SATA nozzle
cleaning needles only. The use of other tools may cause damage or
may affect the spray pattern. Recommended accessory: cleaning kit
Art. No. 64030.
• Exclusively use spray gun washing machines recommended by SATA!
Please observe the operating instructions!
• The air passages have to be pressurised with clean compressed air dur-
ing the entire cleaning process!
• Nozzle head has to point downwards!
• Remove the spray gun from the washing machine after the
cleaning process!*
• Never use ultrasonic cleaning devices - leads to damage of noz-
zle set and gun surface!**
• After cleaning, the spray gun, the material passages, the air
cap including thread as well as the gravity flow cup have to
be blown dry with clean compressed air!*
* otherwise risk of corrosion
** otherwise damage of the electronic components of DIGITAL
spray guns
• Check spray pattern after cleaning the nozzle set!
• Further tips concerning cleaning can be found at www.sata.com/TV.
9.

Maintenance

• Prior to maintenance, disconnect the spray gun from the compressed
air circuit!
• Disassemble and install components very carefully! Exclusively use
included special tools!
Warning! Attention!
,
**
Notice!