Operating instructions SATAjet 5000 B RP/HVLP (DIGITAL)
9.4. Replacing the air piston, air piston spring and
air micrometer
• Disconnect the spray gun from the compressed air circuit!
When air leaks from the air cap or the air micrometer without the trigger
being pulled, they need to be replaced. After disassembly, grease the air
micrometer sleeve with SATA high performance grease (Art. No. 47173),
insert it together with the air piston and tighten the locking screw [10-1].
Adjust material flow according to chapter 7.2 after installation.
• Check if the locking screw has been firmly tightened! The air microm-
eter could shoot out from the spray gun uncontrolled!
9.5. Replacing the sealing (air side)
• Disconnect the spray gun from the compressed air circuit!
Steps: [9-1], [9-2], [10-1], [10-2], [10-3], [10-4] and [10-5]
Replacing the self-adjusting sealing [10-5] is required when air leaks
from under the trigger.
1. After disassembly, please check air piston rod [10-4] and clean it, if
required. If damaged (e.g. if scratched or bent), replace it and grease
with SATA high performance spray gun grease (Art. No. 48173) and
insert. Please observe correct order of installation!
2. Lubricate air micrometer sleeve as well, insert together with air piston
and tighten the locking screw.
After installation, please adjust material flow according to chapter 7.2.
• Check if the locking screw has been firmly tightened! The air microm-
eter could shoot out from the spray gun uncontrolled!
Steps: [10-1], [10-2] and [10-3]
Warning!
Warning!
Warning!
Warning!
EN
125