3.4.
Working with the machine
a.
Loads should be lifted at the lowest possible speed of the winch.
b. Before starting the work with the machine, make sure that the cable is properly wound on
the drum (D).
c.
The steel cable should always be taut before lifting the load.
d. The winch motor has overheating protection. If the system overheats during operation, the
operation will be stopped and resumed after the drive components have cooled down.
e. Caution! The device is not equipped with a load capacity sensor. If the machine is unable to
lift the load, the maximum capacity of the winch has been exceeded. Do not try to lift the
load again! Before working with the unit again, wait until the drive elements of the unit
have cooled down completely.
f.
It is forbidden to use the limit switches as a routine shutdown method for the machine.
These are limit switches, emergency switches that ensure safety in the workplace.
g.
Before working with the unit, make sure that the load is properly attached to the hook of
the carrier rope or the pulley if the winch is equipped with a pulley.
h. When working with the unit, keep a safe distance between the load and the winch cable.
i.
The carrying rope should always be in good condition.
OPERATING THE UNIT
a.
Before each work with the device, check that the emergency switch and the control button
panel are in good technical condition.
b. The load is controlled using the appropriate control buttons (arrows):
a.
b. up or down / left or right (for models MSW-PROCAT-1000NW / MSW-PROCAT-
c.
If, when moving the load "up", the operator does not stop the machine drive below the
level of the limit switch lever, the limit lock will move the lever up and the limit switch will
be activated. The operation of the device will be stopped.
d. If, when controlling the load "down", the operator does not stop the machine drive above
the safe limit of the steel cable on the drum, the lower limit switch lever will be activated
and the machine will be stopped.
e. NOTE: In an emergency, immediately press the red Emergency Stop button! The operation
of the device will be stopped!
f.
You cannot operate the device if the emergency stop has been activated.
g.
In order to resume operation after activating the emergency shutdown:
a.
b. For the / MSW-PROLIFTOR-800NW model, press the START button.
3.5.
Cleaning and maintenance
CAUTION! The continuous operating time of the device is approximately 8,000 cycles * (excluding wearable
parts). In order to ensure safe and trouble-free operation, inspection and maintenance of the entire device
should be carried out after exceeding the service life limit.
Periodic inspection refers to the inspection of the machine after approximately 100 cycles of operation.
The duty cycle refers to raising and lowering the load once.
a)
Pull the mains plug and let the unit cool down completely before cleaning, adjusting or replacing
accessories and when the unit is not in use.
b)
Replace damaged or worn parts on an ongoing basis and keep proper maintenance records.
c)
Periodically check the operation of the limit switches.
•
Carry out a test run without load.
•
Move the load "up". Do not stop the machine drive below the limit switch lever level. The
limit switch should be activated - the operation of the device should be stopped.
up or down (for MSW-ET-250 / MSW-PROLIFTOR-800NW).
800NW).
For the MSW-ET-250 model, unlock the emergency stop button by turning in the
direction of the arrows on the button.