Indoor unit
Fig. 9
For S 32xx models
For the rear-right-hand and rear-left-hand piping, install the piping as shown. Bend the connective pipe
to be laid at 43mm height or less from the wall. (fig. 9 and 10)
1.
Pass the piping through the hole in the wall.
2.
Put the upper claw at the back of the indoor unit on the upper hook of the installation plate, move the
indoor unit from side to side to see that it is securely hooked.
3.
Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit
and the wall. Get it out after finish piping.
4.
Push the lower part of the indoor unit up on the wall. Then move the indoor unit from side to side, up
and down to check if it is hooked securely.
See picture 11:
Do not bend!
Bend
(Only 1 x)
5. Piping and wrapping
Bundle the tubing, connecting cable, and drain hose with tape securely, evenly as shown in Fig.9.
ATTENTION
• Because the condensed water is gathered in ponding box and is piped out of room. Do not put
anything else in the box.
• Connect the indoor unit first, then the outdoor unit. (S 32xx)
4
92
Fig. 10
Bend
(Only 1 x)
Fig. 11
.