Troubleshooting/Maintenance
Troubleshooting Protection Modes
The Inverter may shut down and cease supplying AC power under
certain conditions in order to protect the unit, the battery and the
connected equipment.
The LED automatically illuminates green when the Inverter is plugged
into a 12V DC power source and turned on. If conditions cause the
Inverter's LED to illuminate red, its alarm to sound or the inverter
automatically turns itself off, follow these instructions to restore the
unit to normal operation:
Condition
Low Voltage
Alarm and
Low-Voltage
Cutoff
Overvoltage
Alarm and
Shutdown
Overload
18-06-149-93385F.indb 18
Explanation
When the power input
from the vehicle's battery
drops to approximately
10.5V DC, the low
voltage alarm will sound.
When the voltage goes
down below 10V DC, the
inverter shuts off.
When the power input
from the vehicle's
battery exceeds 16V DC,
high voltage overload
protection occurs and
shuts down the inverter.
The continuous load
demand from the
equipment or device
being operated exceeds
the continuous load
rating of the inverter.
18
Solution
Start the vechicle to
recharge battery the
battery. See Resetting
the Inverter for more
information.
Use a higher capacity
inverter or lower rated
device.