MAINTENANCE
Cleaning the Mesh Filter & Product Storage
Cleaning the Mesh Filter
Cleaning intervals will differ depending on use and water quality.
It is recommended to check the filter at least once a year.
1. Turn off the water supply and hold the toilet's flush lever down
until all of the water has drained from the tank.
2. Unplug the Swash, remove the bidet from the toilet, and
disconnect the bidet hose. You may want to use a bucket to
catch any dripping water from the bidet hose.
3. Remove the Mesh Filter from the water inlet with a pair of tweezers or
needle-nosed pliers.
4. Clean the filter with a toothbrush while running under tap water to
effectively remove any foreign substances or build-up.
5. Replace the Mesh Filter and carefully check that it is installed correctly.
If improperly installed, it could result in the product leaking water.
6. Reconnect the bidet hose and place the seat back on the toilet. Plug the
cord back in, and turn the water supply back on.
Product Storage
Short Term Non-Use
If the product will not be used for more than a few weeks, you can simply unplug it.
You may also consider shutting the water supply off at the wall for extra precaution.
Long Term Non-Use
If the product will not be used for an extended time (longer
than four months), you should unplug the unit, shut the
water supply off at the wall, remove the Swash from the
toilet by forcefully pulling the Swash away from the tank
off of the mounting plate. Remove the bidet hose. To drain
the Hot Water Heater, unscrew the drain plug by turning it
counterclockwise by 90 degrees towards "OPEN," allowing
any residual water to drain out.
Step 3
21