ENGLISH
Relative humidity in different environments suitable for people:
Bedroom, living room: 45-65 % RH
Patient's room: 40-55 % RH
Room with computer, experiment equipment: 45-60 % RH
Room with piano: 40-60 % RH
Museum, exhibition hall, and library: 40-50 % RH
Place the device on a flat surface.
Take out the top cover, fill the water tank and then put the top cover back.
Place the water tank on the main base.
Plug the device to a power supply. The display will light up and the device will beep. After 1
second, the display will turn off and the device will enter standby mode.
Press on/off, the device will start working under mist mode at level 2. The blue light indicator
will turn on. The control panel will display the current humidity and then will display Mist
mode level 2 after 15 seconds. One minute later, it will display current humidity and back to
Mist mode again repeatedly.
Mist speed
While the display shows current humidity, press the Max./Min. button to check the current
mist speed. Press repeatedly to set the desired speed. There are 3 different settings.
Constant humidity
When the LED display is showing current humidity, press the Humidity symbol.
The humidity level can be set from 30 % RH to 90 % RH.
Every time the symbol is pressed, it will be increased by 5 %.
When it reaches 90 %, press again and the display will show "Co". Do not operate the device
for 3 seconds to cancel the humidity setting function.
Note: If the target humidity is higher than the current humidity, the humidification function
will work.
When the set humidity is 16 % RH higher than current humidity, the device will operate at mist
level 3.
When the set humidity is 10 % RH ~ 15 % RH higher than current humidity, the device will
operate at mist level 2.
When the set humidity is 1 % RH ~ 9 % RH, the device will operate at level 1.
When the target humidity is lower than the current humidity, the device will enter standby
mode.
Note: The mist speed cannot be adjusted under constant humidity function.
38
BREEZECARE 3500 WARM
During operation, hold down the humidity symbol for 2 seconds to turn the blue light
indicator and the display on. Touch the symbol again to turn it off. After 15 seconds of no
operation, the light indicators and display will turn off.
Timer
There are 12 timer settings: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10,11, 12 hours.
Press the Timer symbol repeatedly to select the desired operating time.
Press the Timer symbol until "-- --" is displayed or hold down the Timer symbol twice to
cancel the timer.
Once the timer is set, do not touch any button and setting will be automatically saved after 5
seconds. After 1 minute, the display will show the current humidity.
The display will show the remaining time every hour.
Warm water mist
Press the Warm mist button to turn the warm mist function on and off. The warm mist
function indicator will light up.
Note: This function is not available when there is no water in the tank or when it is running
under a non-humidifying mode.
Auto shut-off system
When the tank runs out of water, the device will automatically stop operating. The red light
indicator will turn on.
Refill the water tank, and the device will continue operating with the previous settings. If the
tank is not refilled, the device will turn off after 5 minutes.
Aroma box
Press on the aroma box to remove it from the base and pour aroma oil into the aroma box.
Fig 3.
Warnings:
Never run the humidifier when there is no water in water the tank and water basin.
Only pour aroma oil into the aroma cotton. Do not pour any liquid other than clean water into
the water tank or water base.
4. CLEANING AND MAINTENANCE
Use a soft, damp cloth to clean the surface of the device.
Do not use detergent, scouring pads, chemically treated cloths, gasoline, benzene, alcohol,
thinner, or other solvents, as these can scratch and damage the tank and cause water
leakage.
Do not immerse the product in water or any other liquid.
ENGLISH
BREEZECARE 3500 WARM
39