CONNECTING THE POWER
240AC or 208AC
60HZ
External
thermostat
If you will use an external temperature control (external thermostat) to control
the heater to be operated or not, please follow below attention points:
1. Make sure that the heater's temperature control knob (thermostat knob) is turned
fully clockwise.
2. Connect the wire according to below wiring diagram.
Terminal station
2
LINE
RED
4
External thermostat
INSTALLATION
L1
L2
1
2
E
GND
L1
240AC or 208AC
L2
60HZ
1
External
thermostat
2
1
E
GND
LOAD
BLACK
3
KM
Switch
2500W
2500W
KM
Selected
switch
KM
Switch
2500W
2500W
KM
8
2500W
Heater's
thermostat
Heater's
External
thermostat
thermostat
Selection Switch
(Heater's thermostat, External thermostat)
2500W
Selected
Heater's
switch
thermostat